  Datasheet File OCR Text:
 A1 100RW Series
Miniature, 10W DIP Single & Dual Output DC/DC Converters
Electrical Specifications
Specifications typical @ +25C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
* 10W Output Power * Compact DIP Case * 2:1 Input Voltage Range * Single & Dual Outputs * 1,500 VDC Isolation * Meets EN55022 Class "A" * 1.0 MH MTBF * Industry Standard Pin-Out
Input
Parameter Input Start Voltage Input Filter Reverse Polarity Input Current Short Circuit Input Power Conditions Min. Typ. Max. 12 VDC Input 7.0 8.0 9.0 24 VDC Input 14.0 16.0 18.0 48 VDC Input 30.0 33.0 36.0 (Pi) Filter (Complies with EN55022 Class "A") 0.5 2,500 Conditions Dual Output , Balanced Loads Vin = Min to Max Iout = 10% to 100% Iout = 10% to 100% Over Line, Load & Temp. 150 250 25% Load Step Change 3.0 0.01 Continuous (Autorecovery) Conditions 60 Seconds Flash Tested for 1 Second 500 VDC 100 kHz, 1V Min. 1,500 1,650 1,000 Typ. 110 Min. Typ. 0.6 0.5 0.3 0.7 0.5 50 Max. 1.2 1.0 1.0 1.5 1.2 85 100 15 180 500 5.0 0.02 Units VDC
A mW Units % % % % % mV P - P mV P - P mV rms % Sec % %/C
Output
Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation, 2.5 Vout Models Load Regulation, All Other Models Ripple & Noise (20 MHz) (Note 1) Ripple & Noise (20 MHz) Ripple & Noise (20 MHz) Output Power Protection Transient Recovery Time (Note 2) Transient Response Deviation Temperature Coefficient Output Short Circuit
General
Parameter Isolation Voltage Isolation Voltage Test Isolation Resistance Isolation Capacitance Switching Frequency Max. Units VDC VDC M pF kHz Units
C C C
RoHS Compliant
1,000 400
1,200
Environmental
Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity Conducted EMI Conditions Min. Typ. -40 +25 -40 -40 Free Air Convection RH, Non-condensing EN55022 Class "A" Ambient Case Max. +60 +90 +125 95
MicroPower Direct
292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com
%
Physical
Case Size Case Material Weight 1.25 x 0.80 x 0.40 Inches (31.8 x 20.3 x 10.2 mm) Metal with Non-Conductive Base 0.61 Oz (17.3g) Conditions MIL HDBK 217F, 25C, Gnd Benign Conditions 12 VDC Input 24 VDC Input 48 VDC Input 1.5 mm From Case For 10 Sec All Models Min. 1.0 Min. -0.7 -0.7 -0.7 Typ. Max. Units MHours Units VDC
C
Reliability Specifications
Parameter MTBF
Absolute Maximum Ratings
Parameter Input Voltage Surge (1 Sec) Lead Temperature Internal Power Dissipation Typ. Max. 25.0 50.0 100.0 260 2,500
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model Number A1102RW A1103RW A1104RW A1105RW A1106RW A1107RW A1111RW A1112RW A1113RW A1114RW A1115RW A1116RW A1117RW A1121RW A1122RW A1123RW A1124RW A1125RW A1126RW A1127RW Voltage (VDC) Nominal 12 12 12 12 12 12 24 24 24 24 24 24 24 48 48 48 48 48 48 48 Range 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 9.0 - 18.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 18.0 - 36.0 36.0 - 75.0 36.0 - 75.0 36.0 - 75.0 36.0 - 75.0 36.0 - 75.0 36.0 - 75.0 36.0 - 75.0 Input Current (mA) Full-Load 1,006 1,004 957 968 957 968 377 485 479 479 478 473 478 188 243 239 240 239 236 243 Output Reflected Efficiency Current Ripple Voltage Current (%, Typ) (VDC) (mA, Max) (mA, Min) No-Load Current
(mA, Typ)
Fuse Rating Slow-Blow (mA) 2,000 2,000 2,000 2,000 2,000 2,000 1,000 1,000 1,000 1,000 1,000 1,000 1,000 500 500 500 500 500 500 500
40 40 40 40 40 40 20 20 20 20 20 20 20 10 10 10 10 10 10 10
60 60 60 60 60 60 40 40 40 40 40 40 40 40 40 40 40 40 40 40
3.3 5.0 12.0 15.0 12.0 15.0 2.5 3.3 5.0 12.0 15.0 12.0 15.0 2.5 3.3 5.0 12.0 15.0 12.0 15.0
3,000 2,000 833 666 416 333 3,000 3,000 2,000 833 666 416 333 3,000 3,000 2,000 833 666 416 333
300.0 200.0 83.0 66.6 42.0 33.0 300.0 300.0 200.0 83.0 66.6 42.0 33.0 300.0 300.0 200.0 83.0 66.6 42.0 33.0
82 83 87 86 87 86 83 85 87 87 87 88 87 83 85 87 87 87 88 87
Notes: 1. When measuring output ripple, it is recommended that an external 0.47 F ceramic capacitor be placed from the +Vout pin to the -Vout pin for single output units and from each output to common for dual output units. For noise sensitive applications, the use of 3.3 F capacitors will reduce the output ripple. 2. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 3. Operation at no-load will not damage these units. However, they may not meet all specifications. 4. Dual output units may be connected to provide a 24 VDC or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output common. 5. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (ESR <1.0 at 100 kHz) capacitor be mounted close to the converter. For 12V input units a 12 F is recommended, for 24V input units, a 4.7 F; and for 48V units a 2.2 F. 6. Models with 5.1 VDC outputs are available. Please contact the factory for details. 7. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating.
Derating Curve
Mechanical Dimensions
Pin Connections
Pin 2, 3 9 11 Single -Vin No Pin NC Dual -Vin Common -Vout Pin 14 16 22, 23 Single +Vout -Vout +Vin Dual +Vout Common +Vin
NC: No Connection
Capacitive Load
Output (VDC) F Max 2.5 3.3 5.0 5.1 12 820 15 470 12 220 15 150 2,200 2,200 2,200 2,200
Mechanical Notes:
* All dimensions are typical in inches (mm) * Tolerance x.xx = 0.01 (0.25)
MicroPower Direct
www.micropowerdirect.com
*
292 Page Street Ste D Stoughton, MA 02072
TEL: (781) 344-8226
*
FAX: (781) 344-8481
*
E-Mail: sales@micropowerdirect.com


▲Up To Search▲   

 
Price & Availability of A1115RW

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X